I'm now trying other packages: kernel-2.1.127 + atm0.51 + the Fore
pca200-e
driver v0.40 from the site
http://cleopatra.inescn.pt/padi/pca200e/
. I built the pca200edriver and
atm into the kernel( not as modules) and
reboot successfully. This time i
didn't see any unresolved symbols prompt,
but i run into another problem.
The following is some of the information.
Please help
me.
----------------------------------------------------------------
[root@smart
/root]# sonetdiag
Section BIP
errors: 7
Line BIP
errors: 134513060
Path BIP
errors: 134520108
Line
FEBE: 1073927803
Path
FEBE:
1074424652
Correctable HCS:
134515328
Uncorrectable HCS: 134514172
TX
cells:
-1073743244
RX
cells:
1073927753
[root@smart /root]# sonetdiag -z
Section BIP
errors: 7
Line BIP
errors: 134513060
Path BIP
errors: 134520108
Line
FEBE: 1073927803
Path
FEBE:
1074424652
Correctable HCS:
134515328
Uncorrectable HCS: 134514172
TX
cells:
-1073743260
RX
cells:
1073927753
[root@smart /root]# sonetdiag
Section BIP
errors: 7
Line BIP
errors: 134513060
Path BIP
errors: 134520108
Line
FEBE: 1073927803
Path
FEBE:
1074424652
Correctable HCS:
134515328
Uncorrectable HCS: 134514172
TX
cells:
-1073743244
RX
cells:
1073927753
[root@smart led]# atmsigd -b
atmsigd:SIGD:
/etc/atmsigd.conf not found. - Using defaults.
atmsigd:SIGD: Linux ATM
signaling UNI 3.0, version 0.51 on 0.0.5
atmsigd:SIGD: Acting as USER
side
atmsigd:KERNEL: Added local ATM
address
39.0000.00000000000000000000.00204804F605.00 at itf
0
[root@smart led]# ilmid -b
[root@smart led]#
atmaddr
39.0000.00000000000000000000.00204804F605.00
[root@smart led]#
zeppelin
LECDAT MSG 'main.c': LEC
ESI:00-20-48-04-f6-05
atmsigd:SSCF: sscf_send invoked in state
2/2
CM NERR 'conn.c': connect error:102,Network
dropped connection on reset
LECDAT NERR 'main.c':
Resetting...
atmsigd:SSCF: sscf_send invoked in state
2/2
CM NERR 'conn.c': connect error:102,Network
dropped connection on reset
LECDAT NERR 'main.c':
Resetting...
atmsigd:SSCF: sscf_send invoked in state
2/2
CM NERR 'conn.c': connect error:102,Network
dropped connection on reset
LECDAT NERR 'main.c':
Resetting...
atmsigd:SSCF: sscf_send invoked in state
2/2
[root@smart atm]# cd /proc/atm
[root@smart atm]# cat
devices
Itf Type ESI/"MAC"addr
AAL(TX,err,RX,err,drop) ...
0 pca200e 00204804f605 0 ( 0 0 0 0 0
) 5 ( 18359506 0 18357621 0 0 )
[root@smart atm]# cat lec
Itf
MAC ATM
destination
Status
Flags VPI/VCI Recv VPI/VCI
[root@smart atm]# cat
pca200e:0
device:
internal
name:
PCA-200E-0
PCI bus
number:
0
device
function:
0x0
interrupt
line:
9
physical
rambase:
0xdf000000
virtual
rambase:
0xc4000000
HW address
(ESI):
00:20:48:04:f6:05
Serial
No:
62981
active b1 small buffs:
47
active b1 large buffs:
32
active b2 small buffs:
41
active b2 large buffs:
32
card init
state:
11
cpqueue:
heartbeat
state:
0x336f4f3e
firmware
release:
4.1.12
monitor
release:
12.0
media
type:
MultiMode 155 Mbps OC3 SC
monitor:
boot status
word:
0xce11feed
version
number:
12
device statistics:
PHY_4b5b:
crc_header_errors:
0
framing_errors:
0
PHY_OC3:
section_bip8_errors:
0
path_bip8_errors:
0
line_bip24_errors:
0
line_febe_errors:
0
path_febe_errors:
0
corr_hcs_errors:
0
ucorr_hcs_errors:
0
ATM:
cells
TX:
0
RX:
0
vpi out of
range:
0
vpi no
conn:
0
vci out of
range:
2
vci no
conn:
1560
AAL0:
cells
TX:
0
RX:
0
dropped:
0
AAL4:
SAR
sublayer:
cells
TX:
0
RX:
0
dropped:
0
CRC
errors:
0
protocol
errors:
0
CS
sublayer:
PDUs
TX:
0
RX:
0
dropped:
0
protocol
errors:
0
AAL5:
SAR
sublayer:
cells
TX:
18397397
RX:
18395167
dropped:
0
congestions:
0
CS
sublayer:
PDUs
TX:
18396709
RX:
18394824
dropped:
0
CRC
errors:
0
protocol
errors:
0
AUX:
allocation failures
small
b1:
0
large
b1:
0
small
b2:
0
large
b2:
0
RX
PDUs:
0
receive
carrier:
OFF!
VCCs:
c344ea00 0.5:5
c344e800
0.16:5
[root@smart atm]# ls
devices
lec pca200e:0
pvc svc
[root@smart atm]# cat
pvc
Itf VPI VCI AAL RX(PCR,Class) TX(PCR,Class)
0 0 5
5 0
UBR 0 UBR
0 0 16
5 0
UBR 0 UBR
[root@smart
atm]# cat svc
Itf VPI VCI State
Remote
[root@smart atm]# cd ..
[root@smart /proc]# cat pci
PCI
devices found:
Bus 0, device 0, function
0:
Host bridge: Acer Labs Unknown device (rev
4).
Vendor id=10b9. Device
id=1541.
Slow devsel. Master
Capable. Latency=64.
Non-prefetchable 32
bit memory at 0xe0000000 [0xe0000000].
Bus 0, device
1, function 0:
PCI bridge: Acer Labs Unknown device
(rev 4).
Vendor id=10b9. Device
id=5243.
Slow devsel. Master
Capable. Latency=64.
Bus 0, device 3,
function 0:
Bridge: Acer Labs Unknown device (rev
0).
Vendor id=10b9. Device
id=7101.
Medium devsel. Fast
back-to-back capable.
Bus 0, device 7,
function 0:
ISA bridge: Acer Labs M1533 Aladdin IV
(rev 195).
Medium devsel. Master
Capable. No bursts.
Bus 0, device 9,
function 0:
ATM network controller: Fore Systems
PCA-200E (rev 0).
Medium devsel. Fast
back-to-back capable. IRQ 9. Master Capable.
Latency=32.
Min Gnt=1.Max Lat=1.
Non-prefetchable 32 bit
memory at 0xdf000000 [0xdf000000].
Bus 0, device 10,
function 0:
Ethernet controller: Intel 82557 (rev
2).
Medium devsel. Fast back-to-back
capable. IRQ 5. Master Capable.
Latency=32. Min Gnt=8.Max
Lat=56.
Prefetchable 32 bit memory at
0xe7000000 [0xe7000008].
I/O at 0xd800
[0xd801].
Non-prefetchable 32 bit memory at
0xde800000 [0xde800000].
Bus 0, device 12, function
0:
VGA compatible controller: S3 Inc. Trio32/Trio64 (rev
84).
Medium devsel. IRQ
9.
Non-prefetchable 32 bit memory at
0xd8000000 [0xd8000000].
Bus 0, device 15, function
0:
IDE interface: Acer Labs M5229 TXpro (rev
193).
Medium devsel. Fast back-to-back
capable. Master Capable.
Latency=32. Min Gnt=2.Max
Lat=4.
I/O at 0xd400
[0xd401].
----------------------------------------------------------------------------
------------
Thanks
very much.
Sincerely,
WuTong
Dec
3.